Resolution of a MPGD readout TPC using the charge dispersion signal

Madhu Dixit (Carleton University & TRIUMF)
Email address: msd@physics.carleton.ca
Session: detector/tracking
Requested time: 15 minutes
Abstract submission date: 29 Jun 2004

Abstract:

The Linear Collider (LC) Time Projection Chamber (TPC) goal is to measure ~ 
200 track points with a resolution of better than 100 microns. The target 
resolution is close to the statistical limit from transverse diffusion in the gas. 
Using a new concept of charge dispersion in a  micro pattern gas detector
(MPGD) with a resistive anode, an MPGD readout may enable the TPC to reach
the LC resolution goal. We present here results on cosmic ray track resolution
of a GEM-TPC using the charge dispersion signal. The resolution was 
measured for 2 x 6 mm pads and drift distances of up to 15 cm. The 
dependence of measured resolution on the drift distance is consistent with 
transverse diffusion in the gas.